

Transcrevo a seguir alguns trabalhos
colhidos em Dental Review
( http://www.dentalreview.com.br
) , GOOGLE e BUSCARTUDO, depois de inseir "cefalometria+erro+digital
" e "cefalometria+erro+computador"
http://www.google.com.br/search?hl=pt-BR&q=cefalometria+erro+digital&btnG=Pesquisa+Google&meta=
http://www.google.com.br/search?q=erro+cefalometria&hl=pt-BR&lr=&start=0&sa=N
http://dir2.buscartudo.com.br/anderson/index.php
Estudo Comparativo da Análise Cefalométrica
pelo Método Manual e Computadorizado ( 2000 ).
http://www.apcd.org.br/Biblioteca/Revista/2000/maio_jun/234.asp
Rev da APCD, v.54, n.3, p.234-41, mai/jun. 2000.
Lilina Ávila Maltagliati Brangeli, José Frnando Castanha Henriques, Maria Helena Ferreira Vasconcelos, Guilherme Janson.
RESUMO: Este estudo teve como objetivo comparar
o traçado cefalométrico manual com o computadorizado, utilizando
imagens digitalizadas dos filmes radiográficos. Dois examinadores
experientes realizaram as cefalometrias de 50 telerradiografias em norma
lateral, pelos dois métodos,
em tempos distintos. Os resultados intra- e interexaminadores
demonstraram que, comparando-se os métodos de análise cefalométrica,
para ambos os examinadores, apenas 1 das 16 mensurações
avaliadas apresentou diferença estatística
e houve incorporação de erros em ambos os métodos
empregados e para ambos os examinadores. Os pontos de estruturas dentárias
estavam presentes em todas as medidas que se apresentaram diferentes e
com maior fonte de erro, demonstrando que estes
são de difícil localização,
e as medidas a eles relacionadas, de baixa confiabilidade, para ambos os
métodos empregados.
Algumas considerações sobre os erros
em Cefalometria ( 1998 )
http://www.cleber.com.br/errojoel.html
Goldreich, H.N.; Martins, J.C.R ; Martins, L.P.; Sakima.R.
RESUMO: O artigo faz uma revisão da literatura e discute os resultados das principais investigações sobre os erros em cefalometria. Foi constatado que o erro é uma constante nos dados advindos dos traçados cefalométricos. Embora seja impossível evitá-los totalmente existem cuidados que se iniciam com a tomada da telerradiografia e finalizam com as mensurações, podem diminuir a possibilidade do erro do método. O objetivo do presente artigo é chamar a atenção para o erro, formando uma conciência crítica com relação aos dados que advêm do cefalograma ortodôntico de pesquisadores ou ortodontistas iniciantes.
Erro de reprodutibilidade das medidas cefalometricas das analises de Steiner e de Ricketts, pelo metodo convencional e pelo metodo computadorizado.
MARTINS, L.P.; Santos-Pinto A, Martins JCR, Dias-Mendes A.. Revista da Sociedade Paulista de Ortodontia, Sao Paulo, v.28, n.1, p.4 - 17, jan./fev./mar./ abr. 1995.
Ary dos Santos Pinto
RESUMO: A cefalometria radiográfica culminou com o desenvolvimento de análises cefalométricas cujo propósito era estudar o processo de crescimento e desenvolvimento crânio facial e as mudanças promovidas pela terapia ortodôntica. Este método trouxe inúmeros benifícios para a investigação científica e ao desenvolvimento da ortodontia como atividade profissional. Entretanto, a radiografia cefalométrica não é uma ferramenta tão precisa quanto se possa imaginar, mas sim sujeita a uma série de fatores que podem induzir a erros de tal magnitude que podem afetar a interpretação dos dados obtidos levando a um diagnóstico incorreto, a planos de tratamento limitados ou até inadequados ao paciente. Estimar a precisão de um método é tarefa complexa, porém, é necessário conhecer os principais fatores que afetam a precisão do método de forma a poder controlá-los. Em cefalometria, a condição de repetibilidade representa a variabilidade mínima necessária à prática clínica e a de reprodutibilidade a variabilidade máxima requerida na pesquisa científica. Esta apresentação procurará discutir os problemas de erro do método (cefalometria computadorizada) de forma a permitir uma sua melhor compreensão, visando a adoção de medidas que propiciem seu controle, reduzindo de seus efeitos.
Mais trabalhos, desenvolvidos na Unesp ( Araraquara ), sobre erro em cefalometria, por MARTINS, J.C.R; GOLDREICH, H.N.; MARTINS, L.P.; SAKIMA.P.R. e outros.
Algumas Considerações Sobre os Erros
em Cefalometria ( 2003 )
http://www.ortoperfil.com.br/Biblioteca/DETAIL.asp?idbiblioteca=50&idcategoria=4
Considerações sobre os Erros em Cefalometria
http://www.dentalpress.com.br/revista/1998/janfev98/inedito1.php
Paulo Roberto Tatusuo Sakima
Avaliação das Estruturas Anatômicas
para Sobreposição Cefalométrica Maxilar Utilizando
Telerradiografias em Norma de 45º
http://www.cleber.com.br/TeseEvandro.pdf
Evandro da Silva Bronzi
Paul W. Major et alli
Q. L. You and U. Hägg
A INFORMÁTICA NO CONSULTÓRIO DE ORTODONTIA:
DIRETRIZES ( 1998 )
Carlos Rodrigues Júnior e Cléber Bidegain
Pereira
http://www.cleber.com.br/carlosjun.html
TESE DR. MUSTAPHÁ AMAD NETO
http://www.mustapha.com.br/tese.htm
CONCLUSÕES: Após a análise
dos dados estatísticos obtidos com base nos métodos utilizados
para elaboração dos traçados cefalométricos
em radiografias, concluímos que:
1- houve correlação
positiva, qualitativa e quantitativa, entre todos os métodos utilizados;
2- o método mais reprodutível,
qualitativa e quantitativamente, foi o método manual;
3- dentre os métodos digitais,
o método I scanner foi mais reprodutível que
o método II da mesa digitalizadora, quantitativamente;
4- quando houve discrepância
entre as medidas, estas foram oriundas da determinação errônea
dos pontos cefalométricos.
AVALIAÇÃO DO ERRO DE REPRODUTIBILIDADE DOS
VALORES CEFALOMÉTRICOS APLICADOS NA FILOSOFIA TWEED-MERRIFIELD,
PELOS MÉTODOS COMPUTADORIZADO E CONVENCIONAL
http://www.dentalreview.com.br/ortodontia/orto24.htm
ALBUQUERQUE JÚNIOR, H. R. & ALMEIDA, M. H.
C.
Foi realizado um estudo para avaliar o erro de reprodutibilidade dos valores cefalométricos usados na filosofia Tweed-Merrifield, tanto pelo método computadorizado quanto pelo método convencional. Utilizou-se uma amostra de trinta telerradiografias da cabeça em forma lateral.
CEFALOMETRIA COMPUTADORIZADA ( 1996 )
Cléber Bidegain Pereira
http://www.craneum.com.br/artigos2.htm
A Cefalometria Radiográfica Computadorizada (CRC), com seus programas e sistemas, também é uma maneira de capturar imagens eletrônicas. Nela, a marcação de pontos craniométricos não só possibilita a medição de grandezas, com também elabora o cefalograma. Os programas de CRC atingiram um alto grau de confiabilidade. Testes e pesquisas têm sido feitas, sempre indicando que a CRC é mais precisa que a cefalometria em que as medidas são feitas pelo operador. Não há erro, neste aspecto, pelo computador. Na CRC, persiste o erro, do operador, na marcação dos pontos. Existem duas alternativas para a marcação dos Pontos Cefalométricos: na Mesa Digitalizadora ou direto na tela do computador, com a flexinha do mouse. No primeiro caso é necessário ter a Mesa, o que hoje não constitui problema. No segundo caso, é necessário ter a telerradiografia digitalizada por um excelente scaner e boa técnica, o que também não constitui problemas, pois o próprio Serviço de Documentação Ortodôntica fornece a telerradiografia digitalizada, com alta qualidade. Assim, no nosso entender, qualquer um dos dois sistemas, tanto com a Mesa ou com a tele digitalizada, são excelentes. Aparecem no mercado, agora, sistemas que têm as duas alternativas, para Mesa Digitalizadora e para a tela do Monitor e, também, programas multimídia, em que o computador fala, nos dizendo os pontos que devem ser digitalizados.
ESTUDO CEFALOMÉTRICO COMPUTADORIZADO, EM FORMA
FRONTAL, DE DIMENSÕES LINEARES E ANGULARES EM INDIVÍDUOS
DA RAÇA NEGRA
http://www.dentalreview.com.br/ortodontia/orto24.htm
SILVA, J. J. & OLIVEIRA, M. G.
Esta pesquisa tem como objetivos estabelecer uma relação
entre as dimensões cefalométricas computadorizadas, obtidas
a partir de 40 telerradiografias em norma frontal, de pacientes da raça
negra, de ambos os sexos, dentados e clinicamente simétricos em
vista frontal, e o padrão estabelecido pelo programa SMTC (Sistema
de Medição e Traçado Cefalométrico) para os
indivíduos da raça branca, assim como realizar um estudo
comparativo entre os sexos masculino e feminino, no sentido de avaliar
as dimensões cefalométricas lineares e angulares para os
indivíduos da raça negra, sendo as referidas dimensões
cefalométricas determinadas a partir da análise de Ricketts
frontal, a qual utiliza as medidas lineares que medem as dimensões
transversal da mandíbula, do maxilar, da face, vertical e transversal
nasal, além das medidas angulares que dimensionam a simetria postural
e a linha mediana maxilomandibular.
Cléber Bidegain Pereira
RESUMO: Creemos que la posición ideal de los incisivos, debe obedecer a un conjunto de características para cada paciente en particular. Ningún cálculo de predeterminación generalizado puede ser bueno, pues son demasiados los factores a considerar. No aceptamos ninguno de los métodos usados, que son, el Triángulo de Tweed y el Sistema e Steiner-Holdaway.
Cléber Bidegain Pereira (2002 )
SUMÁRIO:
A proliferação das análises
cefalométricas nos leva a reflexões: que fazer com elas ?
Um dos intens importantes de seleção deve
ser a avalição dos Pontos Cefalométricos utilizados
como referências básicas. A escolha de uma análise
deve iniciar por ai, considerando-se a confiabilidade destes Pontos. Em
princípio sabe-se que os pontos laterais são menos confiáveis
que os sagitais e que alguns Pontos são altamente confiáveis
na Antropologia, mas duvidosos nas telerradiografias. O propósito
desta apresentação é comentar a confiabilidade de
alguns Pontos Cefalométricos.
Cléber Bidegain Pereira ( 1999 )
A Visualização Computadorizada da Expectativa
de Tratamento ortodôntico e/ou Ortognata (VCETOO) é
um método que executa, graficamente, com o auxílio do
computador, aquilo que se espera
acontecer ou pretende-se fazer durante o tratamento.
O computador possibilita, com facilidade, a composição gráfica
desse planejamento, o qual, sendo visualizado previamente, pode ser
mais bem avaliado e reestudado, além de servir como
parâmetro para avaliações subseqüentes.
Observação: Este procedimento
destina-se ao próprio profissional, para
seu estudo e aprendizado. No caso de
ser mostrado ao paciente deverá ser acompanhado
de explicações, por escrito, de que
a VCETOO não é um compromisso
de tratamento.
CEFALOMETRIA EM FUTURO PRÓXIMO ( 1997 )
http://www.cleber.com.br/furutoc1.html
Dr. Cléber Bidegain Pereira
RESUMO: Espera-se que, no futuro, pela evolução de novos sistemas, como as tomografias computadorizadas, imagens em três dimensões, ressonância magnética ou outros meios, seja possível obter imagens com os contornos anatômicos absolutamente nítidos e sem distorções. Poderá, então, o computador, por si só, marcar os Pontos Cefalométricos com facilidade e precisão, não incorrendo no erro humano. No entanto, não se vislumbra, em futuro próximo, a concretização dessa sistemática ideal.
Maria Helena Ferreira Vasconcelos.
RESUMO: Esta pesquisa objetivou avaliar comparativamente dois programas de traçado cefalométrico computadorizado, RADIOCEF 2.0 e Dentofacial Planner 7.02, quanto à confiabilidade e precisão, em relação ao método de traçado manual. A amostra constou de 50 radiografias cefalométricas laterais de boa qualidade, recentemente obtidas, pertencentes à clínica de pós-graduação da diciplina de Ortodontia da Faculdade de Odontologia de Bauru, da Universidade de São Paulo, de pacientes de ambos os sexos, na faixa etária compreendida entre 11 e 24 anos de idade, constituído exemplares de diferentes tipos de má oclusão
CONCLUSÕES: De acordo com a metodologia
empregada, e a partir dos resultados obtidos na comparação
entre os programas de traçado cefalométrico RADIOCEF 2.0,
Dentofacial Planner 7.02 e o método manual, pode-se concluir que:
1) ambos os programas de traçado cefalométrico
computadorizados podem ser confiavelmente utilizados como recursos auxiliares
de diagnósticos, plano de tratamento, acompanhamento e avaliação
de tratamentos ortodônticos, nos âmbitos, clínico e/ou
de pesquisa;
2) o programa RADIOCEF 2.0 pode ser confiavelmente utilizado
para efetuar medições a partir da digitalização
dos traçados, além forma proposta pelo fabricante".
APLICAÇÕES ORTODÔNTICAS DA TOMOGRAFIA
COMPUTADORIZADA ( 2004 )
VOLUMÉTRICA - A Cefalometria em 2D não
morreu
http://www.spo.org.br/orto2004/tomogra.html
Cléber Bidegain Pereira
Nayene Leocádia Manzutti Eid
Com o advento da maravilhosa 3D pensávamos
que a Cefalometria tradicional iria morrer, quase de imediato, perdendo-se
grande parte do extraordinário acervo científico conquistado
com 70 anos de Cefalometria em 2D.
Eis que surge uma fantástica e deslumbrante opção.
Graças aos tomógrafos é possível
radiografar a hemi-face. Isto é, somente o um lado da face,
o que proporciona uma imagem limpa, sem as sobreposições
dos acidentes anatômicos laterais que tanto perturbam a boa marcação
dos pontos laterais.
Cléber Bidegain Pereira
A posição da mandíbula, quando é
tomada a telerradiografia, constitui um fator altamente considerável,
visto que ocorrem variações cefalométricas significativas,
em diferentes posições mandibulares, principalmente nos casos
de maloclusão.
Aplicabilidad clinica de los estudios de crescimiento
y desarollo craniofacial
http://www.geocities.com/ortousta3/rvou1_cyd.pdf
Maria Emma Zalbeh
Reliability of cephalometric analysis using manual
and interactive computer methods ( 1991 )
http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?cmd=Retrieve&db=PubMed&list_uids=1911687&dopt=Abstract
: Br J Orthod. 1991 May;18(2):105-9
Davis DN, Mackay F.
Department of Medical Biophysics, University of Manchester.
This study compares the results of cephalometric analyses
using manual and interactive computer graphics methods. Results are statistically
in favour of the interactive computer system. This study provides a basis
for ongoing research into alternative methods of cephalometric analyses,
such as digitization and automatic landmark identification using sophisticated
computer vision systems.
Assessment of 3-dimensional computer-generated cephalometric
measurements ( 1999 )
http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?cmd=Retrieve&db=PubMed&list_uids=10511666&dopt=Abstract
Am J Orthod Dentofacial Orthop. 1999 Oct;116(4):390-9.
Kusnoto B, Evans CA, BeGole EA, de Rijk W.
The purpose of this study was to assess the reliability of 3-dimensional computer-generated linear and angular measurements produced by different computer algorithms and various combinations of cephalogram projections compared with direct and CT measurements. A computer program was written to provide 4 computer algorithms and 4 combinations of cephalogram projections generating 22 linear and 10 angular 3-dimensional measurements from 20 landmarks. A new technique to produce biplanar cephalograms from a single x-ray source using a special facebow was developed, and its reliability was assessed. Sets of lateral, frontal, and basilar cephalograms of a human dried skull were taken both with 20 radiopaque landmark markers and without markers. Paired t tests based on marker position demonstrated reliability of the facebow; there were no statistically significant differences in repositioning the skull over time using the facebow at P <.05. In the ideal situation, with minimal head rotation and landmark identification error (with the facebow and radiopaque markers), the average error of linear measurements was 1. 5 mm and 3.5(o) for the angular measurements. Subsequent trials evaluated the errors in head position (within 5(o) of head rotation) and in landmark identification (by removing all markers); two-way ANOVA with Scheffe groupings concluded that the vector intercept with manual adjustment algorithm using the lateral-frontal biplanar projection provides not only greater accuracy but also clinical practicality for both linear (mean of 2.2 mm error) and angular (mean of 4.0(o) error) measurements compared with direct or CT measurements (P <.05). The effect of landmark identification error was found to be slightly greater than the head rotation error in the accuracy of 3-dimensional linear and angular measurements (mean, 2.85 mm error for linear and 4.4(o) error for angular measurements). Lastly, this study concluded that linear measurements in the transverse direction were found to have a slightly larger error than vertical measurements. Anteroposterior measurements have the least error.
MM Rousset*,1, F Simonek2 and JP Dubus2
Conclusions: The new method for the correction of radiographic errors in 3D serial cephalometric radiography appears to be sufficiently accurate to justify clinical evaluation.
P. J. Turner and S. Weerakone
Abstract: Objective: A method of cephalometric analysis is described in which cephalometric x-rays were scanned using a flat-bed scanner and transparency hood. Then the image was displayed on a computer monitor for point identification and subsequent cephalometric analysis using dedicated software. The reproducibility of point identification using this method was compared with two other, commonly used, methods.
Conclusion: The results demonstrated that Screenceph is sufficiently accurate to use in a clinical setting but is not yet sufficiently exact for use in research projects owing to hardware limitations.
Genetic programming for Landmark Detection in Cephalometric
Radiology Images ( 2003 )
http://goanna.cs.rmit.edu.au/~vc/papers/KBSIES.pdf
Vic Ciesielski; Andrew Innes Sabu John; John Manutil
Abstract
Development of a non-radiographic Cephalometric System
( 2003 )
http://www.immersion.com/digitizer/case_study_gallery/2500771.pdf
Satoshi Nagasaka; Takeshi Fugimura and Kensuke Segoshi
Brazilian Maxillofacial Surgeons Double as Computer
Gurus to Save Face for Patients
http://www.geomagic.com/advantage/visualization/surgicalplanning-index.php3
Carlos Roberto Sales
Dr. A F Ayoub and other
Abstract: We describe a vision-based three-dimensional facial data capture system designed for the planning of the maxillofacial operations. We describe the system requirements and outline the methods used to develop a complete three-dimensional facial capture system. Our approach is based upon imaging the face using two stereo-pair sets of cameras. Scale-space-based stereo-matching is then used to recover correspondences between each of the captured stereo-pairs. Photogrammetric routines based on adjustment of bundles are used off-line to calibrate the system by imaging a single object that references all cameras to the same co-ordinate frame. This calibration scheme allows us to convert stereo correspondences to world points for each pair of cameras without the need for any subsequent fusion of data. Initial results show that we are able to capture key facial landmarks to within 0.5 mm.
Assessment of 3-dimensional computer-generated cephalometric
measurements. ( 1999 )
http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?cmd=Retrieve&db=PubMed&list_uids=10511666&dopt=Abstract
Am J Orthod Dentofacial Orthop. 1999 Oct;116(4):390-9.
Kusnoto B, Evans CA, BeGole EA, de Rijk W.
Absttract: The purpose of this study was to assess the reliability of 3-dimensional computer-generated linear and angular measurements produced by different computer algorithms and various combinations of cephalogram projections compared with direct and CT measurements. A computer program was written to provide 4 computer algorithms and 4 combinations of cephalogram projections generating 22 linear and 10 angular 3-dimensional measurements from 20 landmarks. A new technique to produce biplanar cephalograms from a single x-ray source using a special facebow was developed, and its reliability was assessed. Sets of lateral, frontal, and basilar cephalograms of a human dried skull were taken both with 20 radiopaque landmark markers and without markers. Paired t tests based on marker position demonstrated reliability of the facebow; there were no statistically significant differences in repositioning the skull over time using the facebow at P <.05. In the ideal situation, with minimal head rotation and landmark identification error (with the facebow and radiopaque markers), the average error of linear measurements was 1. 5 mm and 3.5(o) for the angular measurements. Subsequent trials evaluated the errors in head position (within 5(o) of head rotation) and in landmark identification (by removing all markers); two-way ANOVA with Scheffe groupings concluded that the vector intercept with manual adjustment algorithm using the lateral-frontal biplanar projection provides not only greater accuracy but also clinical practicality for both linear (mean of 2.2 mm error) and angular (mean of 4.0(o) error) measurements compared with direct or CT measurements (P <.05). The effect of landmark identification error was found to be slightly greater than the head rotation error in the accuracy of 3-dimensional linear and angular measurements (mean, 2.85 mm error for linear and 4.4(o) error for angular measurements). Lastly, this study concluded that linear measurements in the transverse direction were found to have a slightly larger error than vertical measurements. Anteroposterior measurements have the least error.
Digital imaging of cephalometric radiographs, Part
2: Image quality ( 1996 )
http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?cmd=Retrieve&db=PubMed&list_uids=8678345&dopt=Abstract
Angle Orthod. 1996;66(1):43-50. Related Articles, Links
Forsyth DB, Shaw WC, Richmond S, Roberts CT.
The aim of this study was to compare the diagnostic quality of conventional cephalometric radiographs with that of digital image counterparts. The random error associated with angular and linear measurements recorded on the digital images was greater than on the conventional radiographs. In addition, there was a systematic error producing statistically significant differences in the majority of angular and linear measurements between the digital images and the conventional radiographs. The errors that occurred with some measurements were of sufficient magnitude to be of clinical significance, particularly in a cephalometric situation where a high degree of accuracy is required. It is therefore suggested that, for digital imaging of cephalometric radiographs, a pixel matrix larger than 512 x 512 with more than 64 gray levels is required to maintain the diagnostic quality of the original radiograph.
Y-J Chen1; S-K Chen; H-W Huang; C-C Yao and H-F Chang
Conclusions: The SP digital cephalometric radiography could yield better or comparable level of performance in landmark identification as its hardcopy, except point Go in vertical direction.
Tsang KH, Cooke MS.
Cephalometric analysis conventionally requires radiographic exposure which may not be compatible with the growing concern over radiation hazards. Recently, the Dolphin Workstation Imaging System introduced to the dental profession a non-radiographic system, called the DigiGraph Workstation which may be an alternative to cephalometric radiography. The aims of this study were to compare the validity and reproducibility of cephalometric measurements obtained from the DigiGraph Workstation with conventional cephalometric radiographs. The sample consisted of 30 human dry skulls. Two replicated sets of lateral cephalograms were obtained with steel ball markers placed at the majority of the cephalometric landmarks. Duplicate tracings prepared from each radiograph were digitized to obtain cephalometric measurements using the computer software, Dentofacial Planner. For the DigiGraph Workstation, double sonic digitizations were repeated twice for each skull, on two occasions. Fifteen angular and one linear measurements were obtained from both methods and these findings compared using ANOVA, paired t-tests and F-tests. All, except one, cephalometric measurement showed significant differences between the two methods (P < 0.0001). The DigiGraph Workstation consistently produced higher values in 11 measurements (mean differences +0.5 to +15.7 degrees or mm) and lower values in four measurements (mean differences -0.2 to -3.5 degrees). The standard deviations of the differences between readings of both methods were large (0.4-5.8 degrees or mm). The reproducibility of the DigiGraph Workstation measurements was lower than that of the radiographic measurements. The method error of the DigiGraph Workstation ranged from 7 to 70 per cent, while that of radiographic tracings was less than 2 per cent. It was concluded that measurements obtained with the DigiGraph Workstation should be interpreted with caution.
COMPARAÇÃO ENTRE O PROCESSO DE MEDIÇÃO MANUAL
E O COMPUTADORIZADO EM ANÁLISES CEFALOMÉTRICAS
MALINI, C. G. E. & ALENCAR, R.
No presente trabalho é apresentado um estudo comparativo entre
o processo de medição manual e computadorizado feito em 102
pacientes.
(10p. 15ref. 3f.) Rev. CRO - RJ
Cod. D29.2.2 - 0600 - 8 E
Dental Reveiw
ESTUDO COMPARATIVO ENTRE MEDIDAS CEFALOMÉTRICAS FRONTAIS DELINEADAS
MANUALMENTE E COMPUTADORIZADAS
MAHL, C. R. W. & FONTANELLA, V.
A partir de uma amostra de telerradiografias em norma frontal da face
de 50 indivíduos adultos, este trabalho avaliou se existem diferenças
entre os valores médios de medidas esqueléticas lineares
e angulares obtidas de cefalogramas delineados manualmente e computadorizados,
utilizando os programas SMTC, OrtoView, Radiocef e Orto Manager.
(8p. 39ref. 7f.) Rev. Fac. Odont. Porto Alegre
Cod. E24.40.2 - 0100 - 8 D
Dental Reveiw
A Comparasion of tradiotional and computadorized methods
of cephalometric analysis. European Journal of Orthodontics
Andrew, Richardson, ( 1981)
Realibility of Cephalometric Analysis Using Manual
an interactive Computer Methods. British Journal of Orthodontics
Davis, D. N., Macklay, F. ( 1981 )
The clinical significance of tracing error in cephalometry.
British Journal of Orthodontics
GRAVELY, J. F., BENZIES, P. M. ( 1974 ).
Facial growth in man studies with the sids of metalic implants. Acta Odontologica Scand., 13:9-31, 1955. BJÖRK, A.
Prediction of mandibular growth rotation. Am J.Orthod.,
St. Louis, 55 585-99, June 1969.
BJÖRK, A.
Sobre algumas variações angulares cranofaciais em brasileiros. – Rev. Fac. Odontologia, São Paulo, 14 (2): 183-8, Jul./Dez.1976. FREITAS, A.; VELLINI – FERREIRA, F.; RUMEL, A.; TANNOUS, L.A
A metal implant study of mandibular rotation. Angle
Orthod., Chicago, 46 (2): 144-50, 1976.
LAVERGNE & GASSON
Analysis and classification of the rotational growth pattern without implants. Brit. J. Orthod. , 9:51-56, 1982. LAVERGNE & GASSON
Horizontal de Frankfurt como base para análise cefalométrica. Am. J. Orthod. And Dentof. Orthop. V.107:537-40, May, 1995. LUNDSTRÖM, A. M.
Growth of mandible studied with the aid of metal implant. Am. J.Orthod, St. Louis, 52 (2): 145-57, 1970. ODEGAARD, J.
AHLQVIST, J., ELIASSON, S., WELANDER, U. The effect of projection errors on angular measurements in cephalometry. Eur J Orthodont, v. 10, p. 353-361, 1988.
ALBUQUERQUE JR., H. R., ALMEIDA, M. H. C. Avaliação do erro de reprodutibilidade dos valores cefalométricos aplicados na filosofia Tweed-Merrifield, pelos métodos computadorizado e convencional. Ortodontia, v. 31, n. 3, p. 18-30, set.-dez. 1998.
BASKIN, H. N., CISNEROS, G. J. A comparison of two computer cephalometric programs. J Clin Orthodont, v. 31, n. 4, p. 231-233, Apr. 1997.
BERGIN, R. Computerized cephalometrics. Acta Odont Scand, v. 36, p. 349-357, 1978.
DAVIS, D. N., MACKAY, F. Reliability of cephalometric analysis using manual and interactive computer methods. Br J Orthodont, v. 18, n. 2, p. 105-109, May 1991.
FORSYTH, D. B., DAVIS, D. N. Assessment of an automated cephalometric analysis system. Eur J Orthodont, v. 18, p. 471-478, 1996.
FORSYTH, D. B., SHAW, W. C., RICHMOND, S. Digital imaging of cephalometric radiography, part 1: advantages and limitations of digital imaging. Angle Orthodont, v. 66, n. 1, p. 37-42, 1996.
FORSYTH, D. B., SHAW, W. C., RICHMOND, S. Digital imaging of cephalometric radiography, part 2: image quality. Angle Orthodont, v. 66, n. 1, p. 43-50, 1996.
GRAVELEY, J. F., BENZIES, P. M. The clinical significance of tracing error in cephalometry. Br J Orthodont, v. 1, p. 95-101, 1974.
HALAZONETIS, D. J. Computer-assisted cephalometric analysis. Amer J Orthodont Dentofac Orthop, v. 105, n. 5, p. 517-521, May 1994.
HOUSTON, W. J. B. A comparison of the reliability of measurement of cephalometric radiographs by tracings and direct digitization. Swed Dental J, v. 15, p. 99-103, 1982. (Supplement) 20. JACKSON, P.
H., DICKSON, G. C., BIRNIE, D. J. Digital image processing of cephalometric radiographs: a preliminary report. Br J Orthodont, v. 12, p. 122-132, 1985.
LOWEY, M. N. The development of a new method of cephalometric and study cast mensuration with a computer controlled, video image capture system. Part I. Br J Orthodont, v. 20, n. 3, p. 203-214, Aug. 1993.
MARTINS, L. P. et al. Erro de reprodutibilidade das medidas cefalométricas das análises de steiner e de ricketts, pelo método convencional e pelo método computadorizado. Ortodontia, v. 28, n. 1, p. 4-17, jan.-abr. 1995.
NIMKARN, Y., MILES, P. G. Reliability of computer-generated cephalometrics. Int J Adult Orthod Orthognath Surg, v. 10, n. 1, p. 43-52, 1995.
PARTHASARATHY, S. et al. Automatic landmarking of cephalograms. Comp Biomed Res, v. 22, p. 248-269, 1989.
RICHARDSON, A. A comparison of traditional and computerized methods of cephalometric analysis. Eur J Orthodont, v. 3, p. 15-20, 1981.
TOURNE, L. P. M. Accuracy of a commercially available digitizer: A new method for assessment of errors in linearity. Angle Orthodont, v. 66, n. 6, p. 433-40, 1996.
BAUMRIND, S.; MILLER, D. Computer-aided head film analysis: The University of California San Francisco method. Am. J. Orthod., v. 78, p.41-65, 1980.
BJÖRK, A.; SKIELLER, V. Normal and abnormal growth of the mandible. A synthesis of longitudinal cephalometric implant studies over a period of 25 years. Eur. J. Orthod., v. 5, p.1-46, 1983.
COOKE, M.; WEI, S. Cephalometric errors: a comparison between repeat measurements and retaken radiographs. Austr. Dent. J., v. 36, p.38-43, 1991.
FERRAZZINI, G. Critical evaluation of the ANB angle. Am. J. Orthod., v.69, p.620-6, 1976.
17.HOUSTON W AND LEE R: Accuracy of different methods of radiographic superimposition on cranial base structures. Eur. J. Orthod., v.7, p.127-35, 1985.
HOUSTON, W. A comparison of the reliability of measurement of cephalometric radiographs by tracings and direct digitization. Swed. Dent. J. Suppl. 15, p.99-103, 1982.
MARTINS, L.P. Erro de reprodutibilidade das medidas das análises cefalométricas de Steiner e de Ricketts pelos métodos convencional e computadorizado. São Paulo, 1993. Tese (Mestrado) - Faculdade de Odontologia de Araraquara da Universidade Estadual Paulista Júlio de Mesquita Filho.
MELSEN, B. The cranial base. Postnatal development of the cranial base studied histologically on human autopsy material. Acta. Odont. Scand., v.32: supplement 62, 1974.
MIDTGARD, J.; BJÖRK, A.; LINDER-ARONSON, S. Reproducibility of cephalometric landmarks and errors of measurement of cephalometric cranial distances. Angle Orthod., v. 44, p.56-61, 1974.
RICHARDSON, A.: A comparison of traditional and
computerized methods of cephalometric analysis. Eur J Orthod, v.3,
p.15-20, 1981.
PORQUE PREFERIR SN AO INVÉS DE FRANKFOURT
PESQUISA NO BURLINGTON GROWTH CENTRE
POSIÇÃO DOS INCISIVOS
POSIÇÃO DA MANDÍBULA NA TOMADA DA RADIOGRAFIA
RECOLOCAÇÃO CEFALOMÉTRICA DA MANDÍBULA
Posição
da Mandíbula na Cefalometria
Posição da Mandíbula na tomada da
Telerradiografia
Plasticidade Alveolar - Crânios de Sambaquis
Plasticidade
alveolar - Estudo no Burlington
DICA PARA TRAÇADO CEFALOMÉTRICO EM DECÍDUOS
INDAGAÇÃO SOBRE INTERPRETAÇÃO
CEFALOMETRIA
EXPECTATIVA DE TRATAMENTO (VCETOO)
HISTÓRIA DA CEFALOMETRIACOMPUTADORIZADA - ENSAIO
A MELHOR ANÁLISE CEFALOMÉTRICA
MEDIDAS NORMAIS EM CEFALOMETRIA
MESAS DIGITALIZADORAS E TELA DO COMPUTADOR
CONSICERAÇÕES SOBRE CEFALOMETRIA
COMENTÁRIO SOBRE CEFALOMETRIA TRIDIMENSIONAL